P.S. Free & New LEED-AP-BD-C dumps are available on Google Drive shared by GuideTorrent: https://drive.google.com/open?id=1_Iu2uUGmRx_2I7MquvBKl0HR698_mjEo
The best way of passing USGBC actual test is choosing accurate exam braindumps. GuideTorrent has latest test questions and accurate exam answers to ensure you clear LEED-AP-BD-C Real Exam. You just need spend your spare time to practice USGBC top questions and review the key points of study guide, it will be easy to clear exam.
Topic | Details |
---|---|
Topic 1 |
|
Topic 2 |
|
Topic 3 |
|
Topic 4 |
|
Topic 5 |
|
>> LEED-AP-BD-C Exam Sample <<
As we always want to do better in this career, our research center has formed a group of professional experts responsible for researching new technology of the LEED-AP-BD-C study materials. The technology of the LEED-AP-BD-C practice prep will be innovated every once in a while. As you can see, we never stop innovating new version of the LEED-AP-BD-C Exam Questions. We really need your strong support. We always adopt the kind and useful advices of our loyal customers who wrote to us and gave us their opinions on their study.
NEW QUESTION # 299
Which rating system is appropriate for a new mixed-use building with 300,000 ft2 (27 871 m2) of residential units, 150,000 ft2 (13 935 m2) hotel and 50,000 ft2 (4 645 m2) of retail space?
Answer: D
Explanation:
New Construction is the appropriate rating system for a new mixed-use building with 300,000 ft2 (27 871 m2) of residential units, 150,000 ft2 (13 935 m2) hotel and 50,000 ft2 (4 645 m2) of retail space. According to the LEED rating system selection guidance1, the New Construction rating system applies to buildings that are being newly constructed or going through a major renovation, and that include any of the following use types: office, retail, hospitality, education, residential, warehouse and distribution centers, or data centers2. The New Construction rating system can also be used for mixed-use buildings that have more than one use type3. Since the project involves new construction of a mixed-use building with residential, hospitality, and retail uses, the New Construction rating system is the most suitable option. The other rating systems are not applicable because they are either specific to one use type (Retail and Hospitality) or to buildings that are not complete at the time of certification (Core and Shell Development). Reference:
LEED rating system selection guidance | U.S. Green Building Council
LEED v4: Building Design + Construction Guide - U.S. Green Building Council LEED v4 Rating Systems | USGBC-LI
NEW QUESTION # 300
What is the system boundary that a building life cycle analysis must be defined to account for?
Answer: C
Explanation:
The system boundary that a building life cycle analysis must be defined to account for is the cradle-to-grave stage, which includes the production, construction, use, and end-of-life stages of the building. This stage covers all the inputs and outputs of the building system, such as materials, energy, water, emissions, waste, and maintenance.
References:
*Life Cycle Assessment of Buildings: Technical Guidance
*Life-cycle assessment - Wikipedia
*Conducting a Life Cycle Assessment - GSA Sustainable ... - SFTool
NEW QUESTION # 301
A new Science Education Center is pursuing LEED certification. Which of the following strategies could be submitted to earn an Innovation in Design credit?
Answer: D
Explanation:
This strategy could be submitted to earn an Innovation in Design credit because it addresses a green building topic not covered by any existing LEED credit. The air-purifying facade material is a novel and sustainable feature that can reduce the environmental impact of the building by removing pollutants from the air and improving the outdoor air quality1.
NEW QUESTION # 302
During preliminary energy analysis, what energy reduction strategies can best help in reducing the energy load in the new building construction project?
Answer: C
Explanation:
During preliminary energy analysis, massing and orientation are energy reduction strategies that can best help in reducing the energy load in the new building construction project. Massing and orientation refer to the shape, size, and direction of the building, which affect the amount of solar heat gain, daylight, and natural ventilation that the building receives. By analyzing the massing and orientation of the building, the project team can optimize the design to minimize the heating, cooling, and lighting energy demand, and enhance the thermal comfort and indoor environmental quality of the building. The LEED v4 Reference Guide for Building Design and Construction states that "the project team should use the results of the analysis to inform the owner's project requirements, basis of design, and design documents"1. The other options, such as green roof, site conditions, and programmatic and operational parameters, are not energy reduction strategies, but factors that influence the energy performance and demand of the building.
References:
*LEED v4 Reference Guide for Building Design and Construction, Integrative Process Credit: Integrative Process, page 811
*Integrative Process Worksheet2
NEW QUESTION # 303
The total land area within a 1/4 mi. (0.40 km) radius of a project boundary consists of 130 acres (53 hectares) and has a residential to nonresidential ratio of 60:40. Within this same total land area, there are 780 dwelling units and 1,600,000 ft2 (148 645 m2) of nonresidential building space. Given these parameters, what are the surrounding residential and nonresidential densities when attempting to achieve Location and Transportation Credit, Surrounding Density and Diverse Uses?
Answer: A
Explanation:
The surrounding residential density is calculated by dividing the total number of dwelling units by the total residential land area. In this case, it would be 780 dwelling units divided by 60% of 130 acres, which equals approximately 13 dwelling units per acre (or 32 dwelling units per hectare).
The nonresidential density, or Floor Area Ratio (FAR), is calculated by dividing the total nonresidential building floor area by the total nonresidential land area. In this case, it would be 1,600,000 ft² divided by 40% of 130 acres, which equals a FAR of approximately 0.47.
These calculations are used when attempting to achieve the Location and Transportation Credit, Surrounding Density and Diverse Uses, under the LEED AP BD+C V4 rating system.
NEW QUESTION # 304
......
We are the fastest to pursue acquiring LEED-AP-BD-C certification; we are the highest to pursue protecting your benefits. Our GuideTorrent ensures the accuracy and the most coverage of LEED-AP-BD-C Certification Exam Dumps. If you purchase LEED-AP-BD-C certification exam dumps, we will ensure that you can get free update service in one year.
New LEED-AP-BD-C Test Vce: https://www.guidetorrent.com/LEED-AP-BD-C-pdf-free-download.html
2025 Latest GuideTorrent LEED-AP-BD-C PDF Dumps and LEED-AP-BD-C Exam Engine Free Share: https://drive.google.com/open?id=1_Iu2uUGmRx_2I7MquvBKl0HR698_mjEo